ASTM D6110 PDF

Charpy for ASTM D and ASTM D Testing and Izod Impact Testers for ASTM D, ASTM D and ASTM E23 Testing. ASTM D defines the method used to determine the resistance of plastic to breakage when impacted in a three point bend configuration, using a pendulum. ASTM D is used to determine the resistance of plastics to breakage by flexural shock as indicated by the energy extracted from standardized pendulum type.

Author: Netaur Faugor
Country: Lesotho
Language: English (Spanish)
Genre: Love
Published (Last): 8 October 2009
Pages: 414
PDF File Size: 14.24 Mb
ePub File Size: 9.12 Mb
ISBN: 399-2-99064-771-9
Downloads: 53822
Price: Free* [*Free Regsitration Required]
Uploader: Malakree

The values obtained can be used for quality control or to differentiate general toughness. The toss energy, or the energy used to throw the free ends of the broken specimen, is suspected to represent a very large fraction of the total energy absorbed when testing wstm dense and brittle materials.

For specimen preparation we suggest the use of either our Motorized Notchvis or Automatic notcher, d110 together with the correct knife will allow the user to notch their samples correctly, according to the test standard.

Such as the plastics, organic glass etc.

ASTM D – Instron

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. As components could fail at stress levels well below the critical fracture stress, accurate determination of impact damage propagation is necessary.

It is widely used in the industries of plastic products, plastic manufacture, petro chemical etc, University, scientific research institute and commodity inspection department. Be aware d611 other differences in machine design do exist. The pendulum is released and allowed to strike through the specimen.

This test method requires specimens to be made with a milled notch see Note 2.

CEAST Series Pendulum Impact Series Impact resilience is one of the most important properties and cost-effective evaluations for material producers, both with respect to product development and quality control. The specimens are standardized in that they have a fixed length and fixed depth, however, the width of the specimens is permitted to vary between limits.

TOP Related  MANOLITO FOUR EYES PDF

Impact specimen notching machine Sample preparation machine for impact tester is used to process the non-metal material impact test specimen, make the notch then do impact test. The fact that a material shows twice the energy absorption of another under these conditions of test does not indicate that this same relationship will exist under another set of test conditions. Any test specimen preparation, conditioning, dimensions and testing parameters required by the materials specification shall take precedence over those required by this test method.

No procedure has been established for estimating the toss energy for the Charpy method. Moreover, manufacturers of the equipment are permitted to use different lengths and constructions of pendulums with possible differences in pendulum rigidities resulting see Section 5.

UL Thermoplastics Testing Center – Charpy Impact Test

Scatter in energy-to-break is thus reduced. Concrete, Asphalt and Rock. Software for Series Systems. The results are reported in terms of energy absorbed per unit d61110 specimen width, or more specifically, the energy absorbed in breaking the specimen which is equal to the difference between the potential energy at the moment of impact and the residual energy.

Note 1—The machines with xstm hammers have been standardized in that they must comply with certain requirements including a fixed height of hammer fall, which results in a substantially fixed velocity of the hammer at the moment of impact. The beam arm is mounted in frictionless bearings, providing high levels of reproducibility and repeatability.

Additionally, the application of an instrumented hammer in conjunction with our Data Acquisition System can help to identify and d66110 failure modes and impact history.

TOP Related  BGV C7 2012 PDF

Some losses due to pendulum arm vibration the amount varying with the design of the pendulum will occur with tough specimens even when the striking nose is properly positioned.

Significant energy losses due to bending and indentation when testing soft materials have also been observed. If two groups of specimens of supposedly the same material show significantly different energy absorptions, critical widths, or critical temperatures, it is permitted to assume that they were made of different materials or were exposed to different processing or conditioning environments. CCSi features these reliable, direct reading Charpy and Izod Impact Testers for the determination of the resistance of plastics and metals to breakage by flexural shock as indicated by the energy extracted from a beam arm apparatus employing either a pendulum—type hammer Charpy Model or an adjustable combination cantilever—pendulum beam arrangement Dual Model.

Different test parameters are specified according to the type of material that the specimen is made of as well as ast type of notch cut in it.

ASTM D6110 Charpy Impact Resistance of Notched Specimens of Plastics

Link to Active This link will always route to the current Active version of the standard. Since many materials especially thermoplastics exhibit lower impact strength at reduced temperatures, it is sometimes appropriate to test materials at temperatures that simulate the intended end use environment. Email addresses must contain the symbol.

Caution must be exercised in interpreting the results of this test method. Bluehill LE for Basic Testing. Hammers of different initial energies produced by varying their effective weightshowever, are recommended for use with specimens of different impact resistance.